For Sale OHMEDA Datex- Modulus SE Anesthesia Machine

  • Asking Price :$7,900.00 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 27, 2024
  • Listing # : 1519895
  • credit-card
  • credit-card
  • credit-card
  • credit-card
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #1519895

  • Condition: Used - Good
  • Brand: OHMEDA
  • Type: Anesthesia Machine
  • Model: Datex- Modulus SE
Product Description

GE Datex-Ohmeda Modulus SE with CO2
The Modulus SE anesthesia machine supplies set flows of medical gases to the breathing system. A large selection of gases, vaporizes, ventilators and monitors gives you control of your system’s configuration.

FEATURES:

Gases and Vaporizers
Comes with O2 (two connections), N2O and air, plus one more cylinder connection for N2O or Heliox.
Holds three vaporizers.
Low leak rates, accurate flowmeters and a minimum proportion of O2 to N2O permit closed circuit and low-flow anesthesia.
Ventilators and Monitors
Available with the 7900 ventilator, a microprocessor controlled ventilator with internal monitors, electronic PEEP, two modes of ventilation and a pressure
waveform display.
Available with the 7800 ventilator, a microprocessor controlled ventilator with internal monitors.
The Modulus SE also accepts the Ohmeda Respiratory Gas Monitor or the Ohmeda Rascal II.

Patient Safety

Patient Safety devices decrease the risk of:
Hypnoxic mixtures: The Link 25 System keeps the O2 concentration higher than 25% (approximate value) at the common gas outlet for O2 and N2O mixtures. N2O and air or heliox flows stop if the O2 supply decreases to less than 20 psig (138 kPa).
Agent mixtures: With correctly installed vaporizers, you cannot turn on more than one vaporizer at a time. The vaporizer manifold prevents gas flow through all vaporizers that are OFF.
Complete power or sudden gas supply failures: Batteries continue 7800 and 7900 ventilator operation during a power failure. Ohmeda ventilators have power
failure alarms, and alarms for low gas supply pressure. The Modulus SE has an alarm for O2 supply pressures less than 30 psig (207 kPa; approximate value).

Ventilator Option 1: 7800
Systems with the 7800 Ventilator use:
The ventilator to monitor inspiratory O2, expiratory volume, and airway pressure.
The system switch to start gas flow and to turn ON the ventilator.
A pneumatic alarm for low O2 supply pressure.
A battery in the ventilator to continue ventilator operation during a power failure.
An outlet box to supply electrical power to system components. A transformer in the box supplies power for the light.

Ventilator Option 2: 7900
Systems with the 7900 Ventilator use:
The ventilator to monitor inspiratory O2, expiratory and inspiratory volumes, and airway pressure.
The system switch to start gas flow and to turn ON the ventilator.
An electronic alarm on the ventilator for low O2 supply pressure.
A battery in the ventilator to continue ventilator operation during a power failure.
Software that adjusts for changes in fresh gas flow, breathing circuit compliance, and leaks.
An outlet box to supply electrical power to system components. A transformer in the box supplies power to the light.
The 7900 Ventilator has two modes of mechanical ventilation. Each mode adjusts the output as necessary to supply the set breath:
The pressure mode supplies constant pressure during inspiration.
The volume mode supplies constant flow during inspiration.

Patient Data:
Inspired O2 concentration.
Exhaled tidal and minute volumes.
Respiratory rate.
Peak, mean, and plateau airway pressures.
Airway pressure waveforms.

Alarms:
High and low O2 concentration.
High, low, sustained, and subatmospheric airway pressures.
Volume apnea.
High and low minute volume (exhaled).
High and low tidal volume (exhaled).
Reverse flow.
The set breath was not supplied.
Empty bellows.
Incorrect control settings.
Incorrect flow sensor connections.
Low Flow/Closed Circuit Anesthesia:
Permits low-flow and closed-circuit anesthesia with:
O2/N2O mixtures in 25%-75% proportions at O2 flows as low as 200 mL/min.
Accurate flowtubes.
Vaporizers with linear concentrations.
Low leak rates.
An absorber that uses less absorbent.

SPECIFICATIONS:

Weight
Modulus SE: 139.3 kg (309.5 lbs.)
Dimensions
SOLD AS IS
ITEM IN PHOTOGRAPH IS WHAT YOU WILL RECEIVE


______________________________________________________________________________________________________________________________________
**The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.

If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item**

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Dr's Toy Store
profile image
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: